Hi, Need Help?

Politique de retour sous 30 jours. En savoir plus

Cliquez ici pour nous contacter.

1107694 | SICK SENSORS | WLD4FP-1H161130A00 Photoelectric Retro Reflective Sensor

₹ 14,469.75

₹ 12,262.50 (Excl. Tax)


Get Best Price on WhatsApp

Product Description

Specification Details
Functional principle Photoelectric retro-reflective sensor
Functional principle detail With minimum distance to reflector (dual lens system)
IO-Link ✔, IO-Link V1.1
Supply voltage UB 10 V DC ... 30 V DC 1)
Ripple ≤ 5 Vpp
Housing Rectangular
Design detail Flat
Dimensions (W x H x D) 16 mm x 40.1 mm x 12.1 mm

 

Warranty

We provide a 1-year warranty from the date of purchase for new products. Additionally, surplus / used items come with a 30-day warranty.

Delivery and Shipping

We aim to process orders within 5-7 business days. Shipping options vary by location with tracking provided; international shipping available with customs duties responsibility on customers.


SPARECRUX is NOT an authorized distributor for SICK SENSORS

Manufacturer Part Number (MPN)

1107694

Original Equipment Manufacturer

SICK SENSORS

PDF Product Datasheet
  • 100% Tested & Verified Products

  • GST Invoice Available

  • Warranty Included

  • Trusted by 5000+ Industrial Buyers

Functional principle – Photoelectric retro-reflective sensor

Functional principle detail – With minimum distance to reflector (dual lens system)

Sensing range min. – 0 m

Sensing range max. – 4.5 m

Maximum distance range from reflector to sensor (operating reserve 1) – 0.015 m ... 4.5 m

Recommended distance range from reflector to sensor (operating reserve 3.75) – 0.035 m ... 3.9 m

Reference reflector – Reflector P250

Recommended sensing range for the best performance – 0.035 m ... 3.9 m

Normative reference – EN 62471:2008-09 | IEC 62471:2006, modified

LED risk group marking – Free group

Wave length – 635 nm

Average service life – 100,000 h at Ta = +25 °C

Supply voltage UB – 10 V DC ... 30 V DC 1)

Ripple – ≤ 5 Vpp

Usage category – DC-12 (According to EN 60947-5-2), DC-13 (According to EN 60947-5-2)

Current consumption – ≤ 20 mA, without load. At UB = 24 V

Protection class – III

Housing – Rectangular

Design detail – Flat

Dimensions (W x H x D) – 16 mm x 40.1 mm x 12.1 mm

Connection – Cable, 4-wire, 2 m

Weight – Approx. 30 g

MTTFD – 747 years

DCavg – 0 %

TM (mission time) – 20 years

EU declaration of conformity – ✔

UK declaration of conformity – ✔

ACMA declaration of conformity – ✔

Moroccan declaration of conformity – ✔

China RoHS – ✔

ECOLAB certificate – ✔

cULus certificate – ✔

IO-Link certificate – ✔

Information according to Art. 3 of Data Act (Regulation EU 2023/2854) – ✔

ECLASS 5.0 – 27270902

ECLASS 5.1.4 – 27270902

ECLASS 6.0 – 27270902

ECLASS 6.2 – 27270902

ECLASS 7.0 – 27270902

ECLASS 8.0 – 27270902

ECLASS 8.1 – 27270902

ECLASS 9.0 – 27270902