Number of outputs 2 x make contacts
Nominal voltage 230 V AC/30 V DC
Load type ohmic, inductive, lamp load
Max. output current 5 A per channel
Switching current 5 A AC/DC (ohmic)/2 A AC/DC (inductive)
Ohmic switching current 5 A AC/DC
Inductive switching current 2 A AC/DC
Minimum permitted load 10 mA at 5 V DC
Lamp test, electronic ballast max. 5 A starting current (4 x 58 W)
Electrical isolation 500 V (K-bus/field potential)
Current consumption power contacts
Current consumption K-bus typ. 85 mA
Bit width in the process image 2 outputs
Operating cycles mech. (min.) 2 x 107
Operating cycles electr. (min.) 1 x 105 (5 A/30 V DC)
Configuration no address or configuration setting
Special features potential-free contacts
Weight approx. 80 g
Operating temperature -25…+60°C
BECKHOFF

KL-2622 | BECKHOFF | Bus Terminal, 2-channel Relay Output, 230 V AC, 30 V DC, 5 A, Without Power Contacts

₹ 12,720.00
Number of outputs 2 x make contacts
Nominal voltage 230 V AC/30 V DC
Load type ohmic, inductive, lamp load
Max. output current 5 A per channel
Switching current 5 A AC/DC (ohmic)/2 A AC/DC (inductive)
Ohmic switching current 5 A AC/DC
Inductive switching current 2 A AC/DC
Minimum permitted load 10 mA at 5 V DC
Lamp test, electronic ballast max. 5 A starting current (4 x 58 W)
Electrical isolation 500 V (K-bus/field potential)
Current consumption power contacts
Current consumption K-bus typ. 85 mA
Bit width in the process image 2 outputs
Operating cycles mech. (min.) 2 x 107
Operating cycles electr. (min.) 1 x 105 (5 A/30 V DC)
Configuration no address or configuration setting
Special features potential-free contacts
Weight approx. 80 g
Operating temperature -25…+60°C