Parameter Specification
Rated Power Supply Voltage 200/220/240 VAC 50/60 Hz
Allowable Voltage Variable Range 85 to 110% of the power supply voltage
Power Consumption Approx. 12 VA (at 240 VAC)
Approx. 3 W (at 240 VAC)
Reset Voltage 10% max. of rated supply voltage
Number of Time Ranges 4
Operation Mode Star-delta
Control Output (Type) Time-limit: SPST-NO (Start operation circuit), SPST-NO (Delta operation circuit)
Control Output (Contact Output) Minimum applicable load: 10 mA at 5 VDC (failure level: P Reference value)
Operating Resetting Time-limit operation / Self-reset
Star-delta Transfer Time Selectable from 0.05 s, 0.1 s, 0.25 s, 0.5 s, 0.75 s and 1.0 s
Ambient Temperature Range Operating: -10 to 55 ℃ (with no icing)
Storage: -25 to 65 ℃ (with no icing)
Ambient Humidity Range Operating: 35 to 85 %
Accuracy of Operating Time ±0.2% FS max.
Setting Error ±5% FS ±50 ms max.
Influence of Voltage ±0.2% FS max.
Influence of Temperature ±1% FS max.
OMRON

H3CR-G8L | OMRON | Solid-State Timer

₹ 2,644.80
Parameter Specification
Rated Power Supply Voltage 200/220/240 VAC 50/60 Hz
Allowable Voltage Variable Range 85 to 110% of the power supply voltage
Power Consumption Approx. 12 VA (at 240 VAC)
Approx. 3 W (at 240 VAC)
Reset Voltage 10% max. of rated supply voltage
Number of Time Ranges 4
Operation Mode Star-delta
Control Output (Type) Time-limit: SPST-NO (Start operation circuit), SPST-NO (Delta operation circuit)
Control Output (Contact Output) Minimum applicable load: 10 mA at 5 VDC (failure level: P Reference value)
Operating Resetting Time-limit operation / Self-reset
Star-delta Transfer Time Selectable from 0.05 s, 0.1 s, 0.25 s, 0.5 s, 0.75 s and 1.0 s
Ambient Temperature Range Operating: -10 to 55 ℃ (with no icing)
Storage: -25 to 65 ℃ (with no icing)
Ambient Humidity Range Operating: 35 to 85 %
Accuracy of Operating Time ±0.2% FS max.
Setting Error ±5% FS ±50 ms max.
Influence of Voltage ±0.2% FS max.
Influence of Temperature ±1% FS max.